Because of their robust design, which includes a reinforcing outer ring configuration and integral pre-filter, Titan3 Syringe Filters are an ideal choice for high solids applications or where maximum confidence is required. Outstanding Performance Low extractable membranes and housings ensure that no filter-borne contaminants are added to your sample Performance-tested under actual HPLC conditions Integral 1mm borosilicate glass pre-filter (30mm devices) ensures greater confidence with high solids samples Reinforcing ring provides greater strength to the housing to prevent leakage and bursting (30mm products pressure rated to 120 psi) Housings are manufactured from solvent-resistant, low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices Able to filter solutions at temperatures up to 100°C Convenient and Easy to Use Color coding makes it easy to select the correct membrane and pore size Packed in re-usable rigid transparent color-coded containers Syringe filters can be sterilized by autoclave at 125°C for 15 minutes Enhanced Luer Lock inlet prevents leakage; outlet fitting is a standard size male Luer-slip fitting for ease of filtrate collection
Sold out
Titan3™ PTFE (Hydrophilic) Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.
Сatalog number:
44525-NPL
Category: Syringeless and Syringe Filters
Description
Additional information
Certifications/Compliance |
Titan3 Polypropylene Syringe Filter Housings Meet The Requirements of 21 CFR 177.1520. |
---|---|
Color |
Purple, Green |
Disposable |
Yes |
Material |
PTFE (Hydrophobic) |
Material (Membrane) |
PTFE (Hydrophillic) |
Pore Size |
0.45 μm, 0.2 μm |
Sterility |
Non-sterile |
For Use With (Application) |
Sample Filtration: aggressive organic, highly basic, or hot solutions, transducer protectors; aqueous solutions after prewetting with an alcohol |
Hold up Volume (After Air Purge) |
<157 μL, <35 μL |
Housing Material |
Medical Grade, Solvent-Resistant, Virgin Polypropylene |
Packaging |
100/Pk., 200/Pk. |
Prefilter |
No |
Pressure Rating |
210 psi, 115 psi |
Product Line |
Titan3 |
Type |
Syringe Filter |
Diameter (Metric) |
30 mm, 17 mm |
Unit Size |
Pack of 100, Pack of,200, Pack of 200 |
Reviews (0)
Be the first to review “Titan3™ PTFE (Hydrophilic) Syringe Filters” Cancel reply
Shipping & Delivery
Related products
Сatalog number:
45025-NN
Titan3™ Nylon Syringe Filters
Offering low extractable membranes and housing, Thermo Scientific™ Titan3™ Nylon Syringe Filters are HPLC performance tested, and color-coded to easily select the correct membrane and pore size. An enhanced Luer Lock inlet prevents leakage. A 1mm boro-silicate glass pre-filter is provided with most 30mm devices, pressure rated to 120psi. This is particularly beneficial with high solids samples that have larger-size particulates. An internal ring provides more strength to the housing which prevents leakage and bursting. Titan3 Syringe Filters are packed in re-usable rigid transparent and color-coded containers.
Сatalog number:
F2502-3
Target2™ PTFE Syringe Filters, 0.45μm, 30mm, with Pre-Filter
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Target2™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Target2 PTFE Syringe Filters are used for general biological filtration. They are especially well-suited for applications where high protein recovery is desired.
Сatalog number:
44525-PV
Titan3™ PVDF Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Titan3™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Titan3 PVDF Syringe Filters are used for general biological filtration. They are especially well-suited for applications where high protein recovery is desired.
Сatalog number:
44525-CA
Titan3™ Cellulose Acetate Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Titan3™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles.Titan3 Cellulose Acetate Syringe Filters are a good choice for filtration of tissue culture media, and for filtration of sensitive biological samples.
Сatalog number:
CH4525-PP
Choice™ Polypropylene (PP) Syringe Filters
Сatalog number:
728-2045PK
Nalgene™ Syringe Filters, Non-sterile
Thermo Scientific™ Nalgene™ syringe filters are built to meet your lab’s clarification and sterilization needs. Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications. Whether your research necessitates prefiltration, sample preparation, sterile filtration, laboratory filtration, or gas venting, Nalgene syringe filters are lab essentials.
Сatalog number:
726-2545
Nalgene™ Sterile Syringe Filters
Thermo Scientific™ Nalgene™ syringe filters are built to meet your lab’s clarification and sterilization needs. Our filters are available in a variety of sizes and membranes that can be easily used for both sterile and non-sterile laboratory applications. Whether your research necessitates prefiltration, sample preparation, sterile filtration, laboratory filtration, or gas venting, Nalgene syringe filters are lab essentials.
Сatalog number:
F2513-2
Target2™ Nylon Syringe Filters
Adding a syringe filtration step prior to injection not only helps to ensure more consistent and reliable results; it also helps protect delicate instruments and prolongs column life.Available in sizes and membrane types to meet any application need, Thermo Scientific™ Target2™ Syringe Filters provide cleaner sample extracts by removing interfering materials and fine particles down to the rated pore size.Target2 Nylon Syringe Filters are a good choice for most general laboratory filtration, as well as filtration of most HPLC samples.
Reviews
There are no reviews yet.