Perform differential pH measurements with a precalibrated plug-and-play sensor using the Thermo Scientific™ AquaSensors™ DataStick™ pH Measurement System. A replaceable reference junction contributes to long sensor life. Direct 24-bit data reporting is done via a variety of direct-to-PLC industrial communication protocols.
AquaSensors™ DataStick™ pH Measurement System
Perform differential pH measurements with a precalibrated plug-and-play sensor using the Thermo Scientific™ AquaSensors™ DataStick™ pH Measurement System. A replaceable reference junction contributes to long sensor life. Direct 24-bit data reporting is done via a variety of direct-to-PLC industrial communication protocols.
SKU:
ASDSPH
Category: Water and Wastewater Systems
Description
Additional information
| Accuracy |
0.1% of reading |
|---|---|
| Range |
0 to 14 pH |
| Step Response Time |
90% in 30 seconds |
| Max. Pressure |
85psig (at 75°C); 100psig (at 95°C ) |
| Type |
pH Measurement System |
| Flow Rate |
10 ft./sec. |
| Resolution |
0.01 pH |
| Temperature (Metric) Operating |
-5°C to +95°C |
| Unit Size |
Each |
Reviews (0)
Be the first to review “AquaSensors™ DataStick™ pH Measurement System” Cancel reply
Shipping & Delivery
Related products
AquaSensors™ Datastick™ ORP Measurement System
SKU:
ASDSORP
AquaSensors™ AquaClear™ DataStick™ Low-Level Turbidimeter
SKU:
AQTC0
Nalgene™ Settlometer Jar with Cover
SKU:
711010-9507
Nalgene™ Settlometer Jar with Cover is a replacement part in the Nalgene™ Settlometer Kit Cat# 1010-0507. The Nalgene™ Settlometer Kit is used to analyze the activated sludge process in waste water treatment plants. The 2L jar is lightweight, transparent, highly impact-resistant and has easy to read white graduations.
AquaSensors™ Datastick™ Dissolved Ozone Measurement System
SKU:
OZPEEK1B
AquaSensors™ AV38 Local Digital Monitor and Controller
SKU:
AV38BB0A1
AquaSensors™ DataStick™ Conductivity Resistivity Sensors
SKU:
CCPEEK
AquaSensors™ AV88 AnalogPlus™ Universal Analyzer
SKU:
AV88
Orion™ AQUAfast COD165 Thermoreactor
SKU:
COD165
Conduct environmental and wastewater monitoring with the Thermo Scientific™ Orion™ AQUAfast COD165 Thermoreactor. The COD165 thermoreactor is equipped with an automatic voltage selector for voltages between 90 and 260 V with a frequency of 50 or 60 Hz. Select from five preset work temperatures of 100 °C, 120 °C, 150 °C, 160 °C and 165 °C and four preset run times of 30 minutes, 60 minutes, 120 minutes or continuous time. Simply place 16mm round sample tubes into the digestor wells, cover with the hinged safety shield, set the temperature and time and let samples digest.

Reviews
There are no reviews yet.